What's New in PTW V6.0?
V6.0 contains lots of new features. It has been
sent automatically to all users with a valid update and maintenance agreement.
Please contact us (using the Contact Us link at the bottom of this page) for a
full list of the new features of V6.0. A summary of the new features is:
- UNDO feature with unlimited steps in one-line diagrams.
- Ability to automatically generate the associated one-line diagram for the
TCC drawing by using the “Go to TCC” feature.
- Display associated one-line diagrams within TCC window as a new tab with
dynamic datablocks based on the most recent study results including: Arc Flash
incident energy, boundary, PPE, etc.
- New Crystal Reports contain industry accepted formats for protective
device settings.
- Ability to plot multiple protection functions of a single device on a TCC
drawing.
- New option in “TCC Settings” > “Fault Current” tab to select a Reference
Device and use its fault current as the reference for shifting and
coordination of the TCCs based on the ratio of the fault current through each
device and the referenced device.
- New Template Library stores typical designs of sub-systems with the
one-line layout and component data. Companies may create templates and set
internal design standard to be used as the building blocks for all projects.
- Contains more than 4,000 new protective device data entries for the Captor
Protective Device Library.
- New VAR Compensation Components: Static VAR Compensator (SVC), Dynamic VAR
Compensator (DVC) and Power Factor Correction Equipment (PFC).
- New Uninterruptible Power Supply (UPS) Component.
- Added several new Transformer sub-type components: Standard Shell,
Standard Core, Auto-Transformer Shell, Auto-Transformer Core and Zig-Zag
Transformer.
- Generator and synchronous motor fault contribution decay is now
represented in the calculation of Arc Flash incident energy.
- Automatically display the Arcing Fault Current flag associated with the
worse case incident energy on TCC drawings.
- Option to combine the “Bus and Line Side” results in Arc Flash Reports and
Labels.
- Option in Arc Flash for status of breakers: Open (racked out) or Closed
(stuck/ failed to open) at the time of arcing fault.
- Print Preview Option for Custom Arc Flash Labels. Multiple labels printing
capability can save time and money.
- Expansion of user-defined fields in Arc Flash PPE Table and Custom Labels.
- New Cable Sizing study program based on IEE Wiring Regulations.
- Display the Maximum or Minimum value from all Scenarios in the Data
Visualizer.
- Includes more global user-defined fields to be automatically used in Print
Forms.
- DC Systems Analysis module contains new NiCAD Battery type and Battery
Sizing based on IEEE 1115-2000 standard.
- I*SIM contains new Double Fed Induction Generator model. Also includes
Wind Generator controller and SVC user-defined graphical models.
|