Unbalanced/Single-Phase Study Module
PTW Unbalanced Studies simulates
systems with single-phase, two-phase and unbalanced three-phase load conditions.
Phase and sequence currents can be displayed for different operating and load
conditions including open-phase and simultaneous faults. Studies include demand
load analysis, sizing, load flow/voltage drop and short circuit. Reports also
include three-phase and single-phase panel schedules. Modelling includes
single-phase, two-phase and three-phase lines, transformers, loads, and
capacitors as well as single-phase mid-tap transformers.
Benefits:
Interface Options:
 |
Display phase or sequence values with
magnitude only, magnitude and angle, magnitude and power factor, or real and
imaginary. |
 |
Display individual phase values, maximum
phase, or phase summation. |
 |
Represent any combination of 1-phase, 2-phase
and 3-phase systems including systems with mid-tap transformers. |
 |
Shares common interface with balanced DAPPER
studies, harmonic analysis, transient stability, equipment evaluation,
reliability, and CAPTOR protective coordination modules. |
Analysis Options:
 |
Connected, demand and design load analysis for
each phase. |
 |
Cable and transformer sizing based on design
load of largest phase. |
 |
Load flow and voltage drop through each
1-phase, 2-phase, and 3-phase branch. |
 |
Representation of transformer automatic
on-load tap-change (OLTC) options. |
 |
Representation of mid-tap transformers. |
 |
Representation of transformer no-load losses. |
 |
Short circuit calculations including
individual or simultaneous faults at different locations and on any phase
combinations. |
 |
Optional capacitance to earth representation. |
 |
Unbalanced load representation in three-phase
and single-phase panels and sub-feeds. |
 |
Cable parameter calculator. |
 |
Sequence to Phase and Phase to Sequence
impedance conversions. |
 |
Transmission line parameter calculator
including multiple circuits, bundling, transposition, and line sag effects. |
Typical Applications:
 |
City distribution systems with three-phase and
single-phase feeds. |
 |
Rural utility distribution systems with
three-phase and single-phase feeds. |
 |
Campus distribution systems. |
 |
Industrial plants to identify normal and
abnormal unbalanced conditions. |
 |
Commercial and institutional buildings with
three-phase and single-phase loads and panels. |
 |
Setting negative sequence relays to detect
abnormal unbalanced conditions. |
Download the brochure in PDF format:
Unbalanced.pdf (42kB)
Download
Acrobat Reader - version 5.0 (or above) required.

|