Arc Flash Evaluation Studies
PTW Arc Flash Evaluation calculates the incident energy and arc flash boundary
for each location in a power system. Arc Flash saves time by automatically
determining trip times from the protective device settings and arcing fault
current values. Incident energy and arc flash boundaries are calculated
following the NFPA 70E and IEEE 1584 standards. Clothing requirements are
specified from a user-defined clothing library. Clearing times can be
automatically reduced based on current-limiting capabilities.

 |
Avoid fires, lost productivity, and litigation
costs. |
 |
Design safer power systems while insuring compliance with NEC
110.16,OSHA, NFPA 70E and IEEE 1584 standards. Save time with the fully
integrated Short Circuit, Over-Current Coordination, Equipment Evaluation,
and Arc Flash Evaluation modules working together with libraries of clothing
levels, protective devices, and bus ratings. |
 |
Provide a safer working environment by specifying the proper level of
clothing. Wearing inadequate clothing is dangerous for obvious reasons, but
wearing too much clothing is dangerous due to limited mobility and
visibility. |
 |
Evaluate alternatives quickly and easily, to establish an optimal
design. |
 |
Improve safety margins with user-definable arcing fault tolerances. |
 |
Save time by automatically generating arc flash labels and work permits. |
 |
Avoid potential fines, lost productivity, and increased insurance and
litigation costs. |
Interface Options:
 |
Simple to use tabular interface for system design, PPE selection, and
reviewing study results. |
 |
Summary and detail view enables complete bus by bus examination of study
data. |
 |
Pre-populated library of protective clothing allows user-defined PPE
additions. |
 |
Bus and branch arcing fault values are automatically calculated and trip
times are automatically determined from the protective device settings. |
 |
Arc Flash labels are automatically produced to comply with NEC 110.16
labelling requirements and can be printed to several standard size label
sheets. |
 |
Create custom labels in any size with user-defined logos, text,
comments, field placement, and local language support. |
 |
Report selected bus locations using custom queries or go-to function. |
 |
Full featured reporting including bus report, line-side report, and
load-side report. |
Study Options:
 |
Option to follow the NFPA 70E or IEEE 1584 standards. |
 |
Option to report in Imperial or metric units. |
 |
Fuses and breakers may be modelled as current limiting devices with
user-defined equations. |
 |
Allows representation of differential, zone-interlocking, photo-sensing,
and other special instantaneous protection schemes. |
 |
Induction motors can be included, excluded, or included for a
user-defined time. |
 |
Automatically accumulates energy from parallel contributions that clear
at different times. |
 |
Compare results from multiple project scenarios in a single table. |
 |
Option to check upstream protective devices for mis-coordination. |
Download the brochure in PDF format:
|